Slide 1 Heading
Lorem ipsum dolor sit amet consectetur adipiscing elit dolor
Click Here
Slide 1 Heading
Lorem ipsum dolor sit amet consectetur adipiscing elit dolor
Click Here

Baudouin diesel Generator Series

Baudouin diesel generator full range of PowerKit products spans from 18 – 4125 kVA, the Baudouin diesel generator most comprehensive range available on the market today. Over 100 years of experience in design, manufacturing, support, and quality goes into every PowerKit. You can expect reliability, durability, excellent total cost of ownership and European quality from our Baudouin diesel generator series. Baudouin engine information

Baudouin diesel generator Uncover our cutting-edge Unified Power Baudouin Powered diesel range, crafted for standby applications or global customers seeking cost-effective solutions. Baudouin Diesel Engines are paired with renowned alternator brands and Deepsea control panels, ensuring unparalleled performance. With a diverse inventory, we address various needs, ensuring that whether you emphasise affordability, emissions, or prompt delivery, we deliver the perfect power solution for your requirements.

Power Range

15-1600kWe

Reliable design

Designed to operate in extreme conditions

Low Cost of Ownership

Low operating costs result from long maintenance intervals

GensetPrimeStandby Engine ModelFuel consumption (Ll/h)Displacement (l)Open typesilent type
ModelKwKvaKwKvaDimension mmDimension mm
UP-BD20151816204M06G17/54.82.3
UP-BD25182320254M06G22/56.12.3
UP-BD35263228354M06G33/57.62.3
UP-BD44324035444M06G44/59.52.3
UP-BD50364540504M06G50/510.72.3
UP-BD55405044554M06G55/511.92.3
UP-BD72526557724M11G70/514.64.5
UP-BD88648070884M10G88/518.84.087
UP-BD11080100881104M10G110/521.34.087
UP-BD1501081351201506M11G150/530.26.75
UP-BD1651201501321656M11G165/532.66.75
UP-BD2201602001762206M16G220/543.19.726
UP-BD2501842302002506M16G250/550.99.726
UP-BD2752002502202756M16G275/556.99.726
UP-BD3852803503083856M21G385/582.19.726
UP-BD4403204003524406M21G440/585.59.726
UP-BD5003604504005006M21G500/5N/A9.726
UP-BD5504005004405506M26G550/5109.515.93800*1600*20505800*1800*2550
UP-BD6604806005286606M33G660/5126.519.63800*1600*20505800*1800*2550
UP-BD7155206505727156M33G715/5136.319.63800*1600*20505800*1800*2550
UP-BD750545.4681.86007506M33G750/5151.119.64500*2100*20805800*1800*2550
UP-BD8256007506608256M33G825/5161.519.64500*2100*20805800*1800*2550
UP-BD880654.5818.172090012M26G900/5173.731.84500*2100*2080ISO 20’ft GP
UP-BD1000720900800100012M26G1000/5195.531.84500*2100*2080ISO 20’ft GP
UP-BD11008001000880110012M26G1100/5207.131.84600*2100*2300ISO 20’ft GP
UP-BD1250908.811361000125012M33G1250/5236.239.24600*2100*2300ISO 20’ft GP
UP-BD1400100012501120140012M33G1400/5258.639.24600*2100*2300ISO 20’ft GP
UP-BD1513110013751210151312M33G1500/5296.939.24600*2100*2300ISO 20’ft GP
UP-BD1650120015001320165012M33G1650/532439.24600*2100*2300ISO 20’ft GP
UP-BD1650120015001320165016M33G1700/5362.152.35400*2650*2650ISO 40’ft HQ
UP-BD1925140017501540192516M33G1900/5396.552.35400*2650*2650ISO 40’ft HQ
UP-BD2063150018751650206316M33G2000/540152.35400*2650*2650ISO 40’ft HQ
UP-BD2200160020001760220016M33G2250/5N/A52.35400*2650*2650ISO 40’ft HQ

Baudouin diesel generator

Baudouin diesel generator Standby Power (ESP)

Baudouin diesel generator Emergency Standby Power is the maximum power available for a varying load for the duration of a main power network failure. The average load factor over 24 hours of operation should not exceed 70% of the engine’s ESP power rating. So Typical operational hours of the  is 200 hours per year, with a maximum usage of 500 hours per year.  That’s why its includes an annual maximum of 25 hours per year at the ESP power rating. No overload capability is allowed. The engine is not to be used for sustained utility paralleling applications.

Data Centre Power (DCP)

Baudouin diesel generator for Data Center. Baudouin Diesel generator are specially designed for data center power solution. Data Centre Power is defined as being the maximum power which a generating set is capable of delivering while supplying a variable or continuous electrical load and during unlimited run hours. So depending on the sites to supply and the availability of reliable utility, the generating set manufacturer is responsible to define what power level he is able to supply to fulfil that requirement including hardware or software or maintenance plan adaptation

generator for data center
Data-Center-Genset

Baudouin diesel generator Prime Power (PRP)

Baudouin Diesel generator for Prime power. Prime Power is the maximum power available for unlimited hours of usage in a variable load application. So the average load factor should not exceed 70% of the engine’s PRP power rating during any 24 hour period. An overload capability of 10% is available, however, this is limited to 1 hour within every 12 hour period.

Emission Control for Baudouin diesel generator

Unified Power is in Joint Venture with top manufacturer of Exhaust Gas purification Technology in China. Our highly motivated international team of specialists continuously test, optimize, and develop new solutions and products. Our products are based on the following technologies:

Connect with us